Reference Projects

Excellence in providing quality services

Reference Projects

Grid Interconnection and Protection Coordination Analysis for
MWSPC well field site(13.8kV/69kV/34.5kV) Saudi Aramco.

ProtectionCoordination Analysis and Relay Settings Calculations
for Waza, Khost andGardez 220/20kV Substation (Afghanistan).

Protection Coordination Analysis and Relay Settings Calculations
including Recloser Settings for several PV Interconnections with
Versant Power USA.

Load Flow Analysis for Distribution Network in Denmark
validation and comparison of results for PSS/E and DIg SILENT
Power Factory with the help of Python Scripting.

Operation Studies for Gulf Cooperation Council Interconnection
Authority (GCCIA) for2020/21 involving GCCIA 400kV Backbone
Network and 6 Gulf Member States.

Protection Settings and Philosophy Study of 884 MW SukiKinari
Hydro Power Plant including Generator Relays, Generator Step up
Transformers (GSUs) Relays, Busbar and Switch yard Protection
Relays, Transmission line Relays etc.

HVDC Engineering Consultancy to US DoE, Virginia Smith
Converter Station, NE (USA): Provided Engineering services to
upgrade the Valve Based Electronics, Protection &Control and
Remedial Action Scheme of 200 MW HVDC Back to Back
asynchronous converter station in Nebraska

Lower ChurchillProject, Muskrat Falls, NL.: Testing and
commissioning ofprotection & control system at High Volatge
Substation

Pasqua SVC Project,Moose Jaw SK.: Installation,Testing &
Commissioning of Static VAR compensator.

NapaneeGeneration Project, Napanee, ON

Suncor Base Plant, Ft. McMurray, AB.

800kV UHVDC Project (CK-1 Project) PowerGrid, Kurukshetra,
IND

Protection Relay settings of complete scope of relays for 747 MW
CCPP Guddu Power Plant, Pakistan.

Protection Relay settings and Philosophy of complete scope of
relays for 50 MW FFC WindPower Plant Pakistan.

Protection Relay settings and Philosophy of complete scope of
relays for 56.4 MW Zorlu Wind Power Plant Pakistan.

ProtectionRelay settings and Philosophy of complete scope of
relays for 50 MW Sachal WindPower Plant Pakistan.

Protection Relay settings and Philosophy of complete scope of
relays for LNG based Bhikki Power Plant, Pakistan.

King Salman Intl’ Complex for Maritime industries & services
(Package 7,8 &9): Detailed Engineering design of overall facility.
Reviewed vendor NMRs onMV/LV Switchgears, Unit Substations,
Transformers, LV MDBs, DC Systems, Stand by Generators, ATS.
Review of all electrical systems engineering deliverables.

FADHLI– Overhead Power Line Networks – Saudi Aramco:
Detailed Design Engineering for installation of 39 no. ESPs.
Conducted Load flow, short circuit, Protection Coordination & Arc
Flash study on entire FDHLI OHPL network using ETAP.

Tadawul Tower Riyadh -- KSA’s First TIER IV Data Centre (2017-
2019): Design, Supply, T&C of LV/MV Electrical systems. Assisted
consultant in prescription of LV Assemblies, LV busways, MV/LV
Transformers, MV Switchgear & RMUs. Reviewed design
submittals from factory. Conducted LV Discrimination study using
Schneider Electric’s Ecodial advanced software & performed MV
Network system studies using ETAP.

Sharma Complex Tabuk Royal Palaces (Mega Project): Design,
Supply, T&C of LV/MV Electrical Systems. Assisted consultant / end
user in prescription of LV Assemblies, MV Switchgear & RMUs
& Attended site technical clarification meetings to get approval on
design packages. Conducted network studies Schneider Electric
Tool (Ecodial advanced), DOC (by ABB) & ETAP software.

Maaden Alumina Refinery (2014-2015): Design, Supply T&C MV/LV
Electrical Distribution Systems. Conducted network studies (Load
Flow, Short Circuit, Protection Coordination & Harmonics Analysis
using ETAP and Ecodial)

Saudi Aramco Southern Area Reliability Enhancement Project
(2017 - 2019): Protection coordination / Selectivity studies for
OHDL Auto reclosers (Schneider make) for complex OHDL
networks (Radial / Looped) feeding Gas Oil Separation
Plants(GOSPs)